Critical Power Supply Solutions in Jordan

Reliable UPS systems, industrial generators, battery backup systems, DC systems, and power conditioning solutions for facilities that cannot afford interruption.

CET helps businesses, institutions, and critical infrastructure protect sensitive equipment, reduce downtime risk, and maintain operational continuity through properly selected, installed, commissioned, and supported power systems.

Online double-conversion UPS cabinet protecting a critical load

Why Critical Power Matters

Power problems are not limited to full outages. Facilities also lose equipment and uptime to voltage dips, surges, frequency instability, harmonic distortion, overheating, battery failure, and unstable distribution. For a bank or data room, that reaches servers and security systems. For a lab, it reaches sensitive testing equipment. For a factory, it interrupts production or damages machinery. CET designs around the actual risks of each facility, not a generic spec.

How CET Supports Your Project

Assessment

Load study, site conditions, redundancy targets, risk points.

Selection

Right topology and brand for the load profile and budget.

Installation

Electrical connection, testing, handover.

Support

preventive maintenance, battery checks, spare-parts planning.

THE POWER CHAIN

0 ms felt by the load

Double-conversion UPS carries the load continuously; the battery rides the gap until the generator picks up. The load never sees the break.

 
UPS SYSTEMS

Uninterruptible Power Supply Solutions

At Critical Energy Technologies, we understand that power continuity is the backbone of daily operations. Our Uninterruptible Power Supply (UPS) solutions are designed to protect critical infrastructure from outages, voltage fluctuations, and electrical disturbances.

Whether you are securing sensitive medical equipment, a high-density data center, a telecom room, a laboratory, a financial institution, or an industrial facility, CET helps select, supply, install, commission, and maintain UPS systems based on your load requirements, runtime needs, site conditions, and long-term support expectations.

Our Core UPS Brands

Riello UPS
Legrand
Salicru
APC
Kehua Tech

CET also supports and maintains selected systems from other major UPS brands when required, including APC, Schneider Electric, Eaton, and Vertiv. Support depends on model, spare parts availability, technical documentation, site conditions, and equipment assessment.

Online Double Conversion 1000KVA Legrand UPS SAVER
UPS Technology
0ms
Transfer time

Online double-conversion rebuilds power from scratch, AC to DC to AC, continuously. Your load never touches raw mains, and never feels the failure.

What CET installs

VFI — Online

0 ms transfer · pure sine wave at all times · full isolation from grid disturbances. The class rated for servers, labs and medical loads.

VI — Line-interactive

2 to 6 ms break on transfer · regulates voltage only. Fine for desktops, not for critical loads.

VFD — Offline

5 to 10 ms break · basic surge protection. The gap alone can reboot sensitive equipment.

 
Equipment Lifecycle

Built to last 15+ years.

A properly maintained three-phase UPS is a 15-year asset — not a 5-year appliance. While others compete on price, we engineer for lifecycle: only three things ever need replacing.

Install & commission

Sized, tested and handed over on load by CET engineers.

Year 5 — batteries

Replace the battery set. That’s the only scheduled change.

Year 7 — fans & capacitors

Preventive swap of cooling fans and capacitors. That’s all.

Year 15 — still on load

Genuine parts and factory service keep it running beyond 15 years.

Factory maintenance programs from Legrand · Riello · Kehua Tech · Salicru.

Generators: built for life. Our Pramac and Generac generator sets are engineered for continuous uptime loads. Serviced on schedule, they run for the life of your facility.
GENERATORS

Industrial Generator Solutions

At Critical Energy Technologies, we deliver industrial generator solutions designed to help facilities continue operating during prolonged grid failures, unstable utility supply, emergency conditions, and temporary power requirements.
Generators are an essential part of a complete critical power strategy. While UPS systems provide immediate backup and protect sensitive loads, generators support longer runtime and larger facility loads during extended outages.

Our Core Generator Brands

Generac
Pramac

CET also works with advanced generator control modules such as Deep Sea Electronics. CET can support, maintenance, or coordinate generator solutions involving other major brands when required, including Cummins, Caterpillar / CAT, SDMO / Kohler, AKSA, EMSA, and Rehlko.

Diesel Generator Solutions In Jordan
Medical Locations · Group 2

Isolated Power Supply (IPS)

In an operating theatre, the supply must not fail on a first insulation fault. A standard earthed system trips. A medical IT system does not.

Operating theatres, intensive care units, catheter labs and dialysis rooms are Group 2 medical locations under IEC 60364-7-710. CET supplies and installs isolated power supply systems built around a medical isolation transformer, an insulation monitoring device, an insulation fault location system, and a theatre alarm panel that tells clinical staff the fault exists — without taking the room off supply.

Leakage current is limited, the first fault raises an alarm instead of an outage, and surgery continues while an engineer locates it. We coordinate the IPS panel with the room’s UPS, generator and equipotential bonding, because in a Group 2 room those layers are one system, not four purchases.

  • IEC 60364-7-710Group 2 medical locations
  • IEC 61558-2-15Medical isolation transformer
  • IEC 61557-8Insulation monitoring device
  • First faultAlarm, not outage — the room stays live
Battery Systems

Service life by chemistry.

The right chemistry for the right application — sized and maintained by CET, supplied by Ultracell, EnerSys and Alcad.

Nickel-Cadmium (NiCd)Harsh climates & switchgear · Alcad
up to 25 years
OPzS floodedTelecom & utility DC · EnerSys
up to 20 years
Lithium-ion (Li-ion)High cycling & compact rooms
up to 15 years
VRLA / AGMUPS runtime · Ultracell / EnerSys
up to 12 years

Manufacturer design life (EUROBAT long-life classes) at 20–25 °C with correct float charging and scheduled maintenance — service life varies with temperature and cycling. CET matches chemistry to your application: UPS runtime, telecom DC, switchgear tripping or solar cycling.

BATTERIES

Battery and DC Power Systems

Battery and DC systems are a critical part of UPS, telecom, industrial, control, and backup power infrastructure. The right battery system affects runtime, reliability, maintenance planning, and system performance.

Battery and DC Brands

Saft
Ultracell
EnerSys
CSB
Alcad

CET can also support or coordinate selected battery replacement and DC power requirements for other major brands when technically suitable.

CHARGER

Rectifiers and Battery Chargers

Rectifiers and battery chargers convert AC power into DC power for battery charging, telecom equipment, control systems, switchgear, industrial systems, and backup power applications.

Charger and Rectifier Brands

Salicru
Sigma
Chloride

CET can also support or coordinate selected battery replacement and DC power requirements for other major brands when technically suitable.

Power Quality

Clean power, not just present power.

Present is not the same as clean. We fix the shape of the wave, not just its supply.

Distorted supply
After CET
Rectifiers & chargersIndustrial DC for telecom, switchgear and control, sized to load and runtime.
Converters & regulatorsStatic and rotary conversion, automatic regulation against sags, surges and brownouts.
Harmonic filters & banksPower-factor correction and harmonic mitigation. Lower penalties, less heat.
REGULATOR

Voltage Regulators and Power Stabilization

Voltage fluctuations can damage equipment, reduce performance, create nuisance faults, and shorten the lifespan of sensitive electrical systems. Voltage regulators help stabilize incoming power and protect equipment from unstable voltage conditions.

Salicru

CET can also source or support other suitable voltage regulation systems depending on the site and technical requirements.

CONVERTER

Frequency Converters

Frequency converters are used when equipment requires a different frequency than the available electrical supply. They may be required for specialized industrial equipment, imported machinery, aviation, marine, testing, defense, or technical applications.

Salicru
Riello UPS

CET can also source other frequency converter solutions depending on project requirements.

FILTER

Harmonic Filters and Capacitor Banks

Some facilities need more than backup power. They need stable, clean, and properly conditioned electrical power. Harmonic distortion, poor power factor, and power quality issues can create heat, increase losses, reduce equipment life, and affect system performance.

ABB
Legrand

CET can also support other suitable brands depending on the electrical study, project requirements, and equipment availability.

Engineering First

Sized right from day one.

An oversized UPS wastes capital and runs inefficiently. An undersized one fails on the worst day. Every CET quotation starts with a sizing study — free.

01

Load audit

We measure real kW / kVA, inrush and power factor — not nameplate guesses.

02

Growth headroom

20–30% spare capacity, so tomorrow’s expansion doesn’t need a new UPS.

03

Runtime target

Batteries sized to bridge to generator — or to ride out the full outage.

04

Redundancy

N+1 parallel systems where a single failure can never drop the load.

The CET Standard
2YEARS
Full warranty

On every product we sell.
As standard. Not an upgrade.

Twice the market standard

The industry norm is 1 year. CET covers every UPS, generator, battery and power system for 2 full years — because we trust what we engineer and install.

CET Standard2 yearsParts, labour and technical support included, from the day we commission.
Typical Market1 yearOften parts only — labour, transport and batteries billed separately.

Seen a longer sticker? Read the terms. “Extended” warranties often exclude parts, labour or batteries — coverage that excludes the expensive parts isn’t coverage. Ours is simple: two full years on the equipment, with only the standard site-visit fee applying.

CONTACT INFORMATION

Let’s talk about building something dependable